Graph scaling reference

X-axis scaling modes

Mode

Behaviour

Full auto-scale

The x-axis always spans the full extent of all logged data.

Sliding window

The x-axis shows a fixed-width time window ending at the most recent sample. The window width is set in seconds (1–9999).

Manual

The x-axis range is controlled entirely by drag and scroll. ModbusScope sets this mode automatically when you drag or use the zoom rectangle.

Y-axis and Y2-axis scaling modes

Mode

Behaviour

Full auto-scale

The y-axis spans all data values across the entire logged time range, even if some are outside the visible x-window.

Window auto-scale

The y-axis spans only the values visible in the current x-window. As you pan or zoom the x-axis, the y-axis rescales to fit.

Limit from / to

The y-axis is fixed at a user-defined minimum and maximum. Enter the values in the Scale options panel.

Manual

The y-axis range is controlled entirely by drag and scroll. Set automatically when you drag the y-axis or use the zoom rectangle.

Mouse interactions

Action

Result

Scroll wheel (no axis selected)

Zoom both axes simultaneously, centred on the cursor

Click an axis label, then scroll

Zoom that axis only

Drag (no axis selected)

Pan both axes

Click an axis label, then drag

Pan that axis only

Double-click an axis label

Reset that axis to auto-scale

Zoom toolbar button, then drag a rectangle

Zoom into the selected area; all affected axes switch to Manual

See also