Device settings reference

Open via Project > Settings… and select the Devices page. Each device has its own tab; use the + button to add one.

A device represents one Modbus slave. Each device is linked to a connection and carries the Modbus-protocol parameters for that slave.

Settings

Setting

Type

Default

Description

Name

String

—

User-visible label for the device

ID

Integer

—

Internal ID used in register expressions (@DEVICE)

Protocol adapter

Selection

—

Which protocol adapter this device uses

Slave ID

Integer 1–247

1

Modbus unit address of the slave

Timeout

Integer (ms)

1000

Time to wait for a response from this device before reporting a timeout. Overrides the connection-level timeout for this device

Max consecutive registers

Integer

125

Maximum number of registers fetched in a single Modbus read request. Reduce if the device rejects large requests

32-bit little-endian

Checkbox

Off

When on, 32-bit values (32b, s32b, f32b) are read in little-endian word order. Must match the device